Compact Gas Sensors

Proven reliability and maximum performance in a compact housing. Suitable in most of all applications.


FeaturesDimensions
Air vent on the back
O-ring on the front
Conforms to 7-Series
Diameter: 32 mm
Height: 17 mm
Pin diameter: 1.0 mm

Data sheet: Click on the sensor type to obtain a PDF document with the specification of the sensor.

This list is not complete. Please ask, if you do not find the sensor you are looking for.

Sensor TypeSensitivity [nA/ppm]Features / Application
AsH3, Arsine
AsH3/C-14200 ± 800highly sensitive
CH2O, Formaldehyde
CH2O/C-104600 ± 1200highly sensitive
CH2O/C-100090 ± 20 
CH2O/CA-101500 ± 500highly selective
CH2O/CA-100180 ± 60highly selective
C2H2, Ethyne, Acetylene
C2H2/CF-202000 ± 400highly sensitive
C2H2/CF-200500 ± 100 
C2H2/CF-200050 ± 10 
C2H4, Ethene, Ethylene
C2H4/C-10400 ± 120highly sensitive
C2H4/C-150011 ± 5 
C2H4/C-200100 ± 30 
C2H4/CA-10350 ± 120highly selective
C2H4O, Ethylene Oxide
ETO/C-100130 ± 30 
ETO/C-100080 ± 15 
ETO/C-202500 ± 600highly sensitive
ETO/C-500023 ± 6 
ETO/CA-201600 ± 400 
RCOOH, Organic Acids
Acid/C-10090 ± 60Measurment of organic acids
R3COH, Alcohols
Alc/C-1001600 ± 600Methanol / Ethanol Measurement
Alc/C-1000120 ± 20Methanol / Ethanol Measurement
CO, Carbon Monoxide
CO/C-1000100 ± 20 
CO/C-200900 ± 300highly sensitive
CO/CF-1000100 ± 20with filter
CO/CF-10000-4E15 ± 4Hydrogen compensated
CO/CF-200700 ± 200highly sensitive, with filter
CO/CF-200-4E470 ± 120Hydrogen compensated
CO/CF-200050 ± 10Emission Monitoring
CO/CF-2000-4E75 ± 25Hydrogen compensated
CO/CF-400030 ± 6Emission Monitoring
CO/CF-400006 ± 2Emission Monitoring
CO/CF-500200 ± 40with filter
CO/CFA-1000100 ± 20highly selective
CO/CFA-1000015 ± 4highly selective
CO/CFA-200550 ± 150highly selective
CO/CFA-500160 ± 30highly selective
CO/CFA-500030 ± 5highly selective
CS2, Carbon Disulfide
CS2/CF-100200 ± 80highly selective
CS2/CF-500100 ± 20 
Cl2, Chlorine, Br2, Bromine
Cl2/C-20900 ± 250highly sensitive
Cl2/C-200140 ± 35 
Cl2/C-200010 ± 3 
Cl2/C-50004 ± 1 
ClO2, Chlorine Dioxide
ClO2/C-200140 ± 35 
ClO2/C-5900 ± 300 
H2, Hydrogen
H2/C-200023 ± 8highly sensitive
H2/C-200006 ± 4 
H2/C-400004 ± 3 
H2/C-50009.5 ± 2.5 
H2/CA-100028.5 ± 11.5highly selective
H2/CB-100028.5 ± 11.5more gastight
H2/CT-1000012 ± 6at high humidity
H2/CT-400004 ± 3at high humidity
H2O2, Hydrogen Peroxide
H2O2/CB-1001100 ± 300highly sensitive
H2O2/CB-200050 ± 10 
H2O2/CB-500300 ± 60 
H2O2/CB-500025 ± 5 
H2S, Hydrogen Sulfide
H2S/C-104500 ± 1000highest sensitivity
H2S/C-1000100 ± 20 
H2S/C-200370 ± 80 
H2S/C-200050 ± 10 
H2S/C-501700 ± 300highly sensitive
H2S/C-500025 ± 6 
H2S/CG-100550 ± 110more gastight
H2S/CG-100-4E540 ± 110Hydrogen compensated
H2S/CG-1000015 ± 5more gastight
H2S/CG-200050 ± 9more gastight
H2S/CG-500020 ± 9more gastight
H2S/CG-5000-4E25 ± 6Hydrogen compensated
HCl, Hydrogen Chloride
HCl/C-100020 ± 7short response time
HCl/C-20450 ± 150highly sensitive
HCl/C-200100 ± 35short response time
HCl/C-300015 ± 5short response time
HF, Hydrogen Fluoride
HF/C-10110 ± 40 
HF/CI-10600 ± 200highly sensitive
HCN, Hydrogen Cyanide
HCN/C-100600 ± 150highly sensitive
NH3, Ammonia
NH3/CR-100025 ± 8short response time
NH3/CR-100002.5 ± 0.5short response time
NH3/CR-200112 ± 40highly sensitive
NH3/CR-50007 ± 2short response time
NO, Nitric Oxide
NO/C-13000 ± 1200highest sensitivity
NO/C-100550 ± 110 
NO/C-252000 ± 400highly sensitive
NO/CF-100400 ± 80with filter
NO/CF-2000100 ± 20Emission Monitoring
NO/CL-1-4E3000 ± 1200for lowest gas concentrations
NO/CL-4E1800 ± 400temperatur compensated BL
NO2, Nitrogen Dioxide
NO2/C-12500 ± 1000highly sensitive
NO2/C-201100 ± 300highly sensitive
NO2/C-500370 ± 70Emission Monitoring
NO2/CA-2650 ± 150highly sensitive, with O3 filter
O2, Oxygen
Not available in this housing 
O3, Ozone
O3/C-100650 ± 150 
O3/C-1000170 ± 30 
O3/C-200400 ± 130 
O3/C-51500 ± 500highly sensitive
O3/C-500030 ± 10 
OX, Ozone, Nitrogen Dioxide
Not available in this housing 
PH3, Phosphine
PH3/C-1000100 ± 25short response time
PH3/C-200070 ± 20short response time
PH3/C-400030 ± 8short response time
PH3/C-54400 ± 1600highly sensitive
SiH4, Silane
SiH4/C-200300 ± 100 
SiH4/C-501200 ± 400highly sensitive
SO2, Sulfur Dioxide
SO2/C-15000 ± 1500highly sensitive
SO2/C-100370 ± 70 
SO2/C-201000 ± 300highly sensitive
SO2/C-2000100 ± 20 
SO2/C-500280 ± 50
SO2/CF-100370 ± 70with filter
SO2/CF-1000020 ± 5with filter
SO2/CF-20550 ± 150highly sensitive, mit Filter
SO2/CF-2000100 ± 20Emission Monitoring
SO2/CF-500280 ± 50with filter
VOC, Volatile Organic Compound
VOC/C-1000020 ± 5 
VOC/C-201800 ± 400highly sensitive
VOC/C-200500 ± 200 
VOC/C-2000200 ± 50 

This list is not complete. Please ask, if you do not find the sensor you are looking for.