Sensor Type | Sensitivity [nA/ppm] | Features / Application |
---|---|---|
AsH3, Arsine | ||
Not available in this housing | ||
CH2O, Formaldehyde | ||
Not available in this housing | ||
C2H4, Ethene, Ethylene | ||
C2H4/S-1500-S | 11 ± 5 | |
C2H4/S-200-S | 100 ± 30 | |
C2H4O, Ethylene Oxide | ||
Not available in this housing | ||
RCOOH, Organic Acids | ||
Not available in this housing | ||
R3COH, Alcohols | ||
Not available in this housing | ||
CO, Carbon Monoxide | ||
CO/S-1000-S | 100 ± 20 | |
CO/SF-1000-S | 100 ± 20 | with filter |
CO/SF-10000-4E-S | 17 ± 4 | Hydrogen compensated |
CO/SF-200-4E-S | 500 ± 200 | Hydrogen compensated |
CO/SF-200-S | 700 ± 200 | highly sensitive |
CO/SF-2000-S | 50 ± 10 | Emission Monitoring |
CO/SF-2E-S | 100 ± 20 | 2-electrodes sensor |
CO/SF-4000-S | 30 ± 6 | Emission Monitoring |
CO/SF-40000-S | 7.3 ± 1.5 | Emission Monitoring |
CO/SFA-10000-S | 15 ± 4 | highly selective |
CO/SFA-200-S | 550 ± 150 | highly selective |
CO/SGF-4E-S | 80 ± 25 | Hydrogen compensated |
CS2, Carbon Disulfide | ||
Not available in this housing | ||
Cl2, Chlorine, Br2, Bromine | ||
Cl2/S-20-S | 900 ± 250 | highly sensitive |
ClO2, Chlorine Dioxide | ||
Not available in this housing | ||
H2, Hydrogen | ||
H2/S-10000-S | 6 ± 4 | |
H2/S-2000-S | 20 ± 5 | highly sensitive |
H2/SA-1000-S | 28.5 ± 11.5 | highly selective |
H2O2, Hydrogen Peroxide | ||
Not available in this housing | ||
H2S, Hydrogen Sulfide | ||
H2S/S-10-S | 4000 ± 1000 | highly sensitive |
H2S/S-10000-S | 15 ± 5 | |
H2S/S-50-S | 1700 ± 300 | highly sensitive |
H2S/SG-10000-S | 15 ± 5 | |
H2S/SG-200-S | 370 ± 80 | more gastight |
H2S/SG-2000-S | 50 ± 9 | more gastight |
H2S/SG-50-S | 1700 ± 300 | more gastight |
HBr, Hydrogen Bromide | ||
Not available in this housing | ||
HCl, Hydrogen Chloride | ||
Not available in this housing | ||
HF, Hydrogen Fluoride | ||
Not available in this housing | ||
HCN, Hydrogen Cyanide | ||
Not available in this housing | ||
NH3, Ammonia | ||
NH3/SR-1000-S | 25 ± 8 | |
NH3/SR-200-S | 90 ± 18 | |
NO, Nitric Oxide | ||
NO/S-100-S | 550 ± 110 | |
NO/S-25-S | 2000 ± 400 | highly sensitive |
NO/SF-1000-S | 200 ± 50 | Emission Monitoring |
NO/SF-200-S | 275 ± 55 | |
NO/SF-5000-S | 40 ± 10 | Emission Monitoring |
NO/SGF-2000-S | 100 ± 20 | Emission Monitoring |
NO2, Nitrogen Dioxide | ||
NO2/S-1000-S | 170 ± 30 | |
NO2/S-20-S | 1100 ± 300 | highly sensitive |
NO2/S-5000-S | 40 ± 10 | |
NO2/SG-500-S | 370 ± 70 | Emission Monitoring |
O2, Oxygen | ||
Not available in this housing | ||
O3, Ozone | ||
O3/S-5-S | 1500 ± 500 | |
OX, Ozone, Nitrogen Dioxide | ||
Not available in this housing | ||
PH3, Phosphine | ||
Not available in this housing | ||
SiH4, Silane | ||
Not available in this housing | ||
SO2, Sulfur Dioxide | ||
SO2/S-20-S | 1000 ± 300 | highly sensitive |
SO2/S-2000-S | 100 ± 20 | Emission Monitoring |
SO2/SF-100-S | 370 ± 70 | with filter |
SO2/SF-10000-S | 20 ± 5 | Emission Monitoring |
SO2/SF-400-S | 200 ± 50 | Emission Monitoring |
SO2/SGF-2000-S | 100 ± 20 | Emission Monitoring |
VOC, Volatile Organic Compound | ||